CM52161 Halogen Acid Gas Release Determination Device


This equipment is used to measure gas volume of Halogen Acid (IEC 60754-1), pH concentration (PH Meter, Hydrogen ions, IEC 60754-2), Conductivity (IEC 60754-2) and etc from a wire (cable) by radiant heat in the Tube Furnace (IEC 60754-1: 800℃, IEC 60754-2: 950℃)

info@cabmac.com

Product Introduction



1.Product presentation
Halogen, PH & conductivity tester is used to measure gas volume of Halogen Acid (IEC 60754-1), pH concentration (PH Meter, Hydrogen ions, IEC 60754-2), Conductivity (IEC 60754-2) and etc from a wire (cable) by radiant heat in the Tube Furnace (IEC 60754-1: 800℃, IEC 60754-2: 950℃)
MCN: 9027100090
2. Standard:
  • IEC 60754-1~2-2019
3. Main technical parameters:
  • Activated Carbon (air filtering): filter for filtering the supplied air
  • Silica Gel (air drying): a device for drying the supplied air
  • Flowmeter: 0.1~1 L/min, a device to control the flow of the air source
  • Thermocouple: K type of high temperature resistant stainless thermocouple, range: 0 ~1300℃
  • Quartz Tube: Φ40×800
  • Magnetic Stirrer: an stirrer used for mixing combustion gas in distilled water
  • PH Meter: a device used for measuring the pH acidity (ray magnetic)
  • Conductivity Meter: a device for measuring conductivity of combustion gas (ray magnetic)
  • 7 "color Touch screen and PLC and PID automatic calculation of the module control heating furnace temperature
  • Heating Furnace: Φ220×600. effective heating space: Φ43×550. power: 4 KW
  • Washing Bottle: 500 ml straight tube bottle washing, quantity: 3, 2 L measuring cup, quantity: 1
4. Specifications
  • Dimensions: Main unit 1200 mm(W) x 520 mm(D) x 725 mm(H)
  •                      Placement table 2500 mm(W) × 600 mm(D)
  • Power Supply: AC220 V, 50/60 Hz, 21 A
  • Reagents, glassware, gas source (provided by the customer)

Keywords:

CM52161 Halogen Acid Gas Release Determination Device

Related Machines



CM42149 Pressure Test Device at High Temperature

Pressure test device at high temperature is used in the indentation of the wire and cable insulation being produced at high temperature and pressure. To test the high temperature resistance and high pressure resistance deformation ability under thermal and mechanical loads simultaneously.

View More →

CM42043 Hot Set Test Device

This equipment is used in conjunction with the high-temperature oven, specimens are hung in the device and placed in an oven, and put the weights on the lower grip of specimens, after 10 minutes, measure the distance between the marks and calculate the elongation.

View More →

CM52160 Fluorine Content Measuring Instrument

The instrument is a perfect combination of advanced electronic technology, sensor technology, and software design, and is the most cost-effective laboratory fluoride concentration analysis instrument. It is widely used for the testing and analysis of fluoride in drinking water, surface water, seawater, domestic sewage, and industrial wastewater, as well as the determination of fluoride in mineral materials, organic materials, and biological materials.This instrument is built-in microprocessor chips, nice appearance, user-friendly with the following outstanding features.

View More →

CM52161 Halogen Acid Gas Release Determination Device

This equipment is used to measure gas volume of Halogen Acid (IEC 60754-1), pH concentration (PH Meter, Hydrogen ions, IEC 60754-2), Conductivity (IEC 60754-2) and etc from a wire (cable) by radiant heat in the Tube Furnace (IEC 60754-1: 800℃, IEC 60754-2: 950℃)

View More →

Product Message

*Attention: Please ensure accurate information filling and maintain smooth communication. We will contact you as soon as possible



Please upload files in RAR or ZIP format.
Submit Message

I WANT TO LEAVE A MESSAGE

If you have any suggestions or are interested in collaboration, please contact us via the following methods. We will respond as soon as possible. Thank you!